Choosing a Boat Heater (Part One)
Monday, January 16, 2017TheCambrians
When we arrived in the Pacific Northwest eight years ago, Cambria lacked one vital piece of equipment for cruising
the Inside Passage: a heater. So, one of the first things we did was to
rectify that. David started researching our options while we were still in California and by the time we rounded Cape Flattery, he’d made a decision.
Like
everything else on a boat, heating presents some issues that can be difficult
and expensive to overcome – available space for equipment and ducting, access
to outside air, multiple cabins to heat (to name just a few). But there are
several types of marine heaters* on the market and choosing the right one is an
important step in overcoming these challenges.
Bulkhead-Mounted Diesel Heaters
![]() |
| Photos courtesy of Dickinson Marine. |
Dickinson
and others make bulkhead and floor mounted units (also known as potbelly
burners) that resemble a piece of art. With the right boat, this would have
been my preference. I love the idea of a working fire and, had we been able to
go the wood-burning route, collecting fuel from the beach would have become a
fun pastime.
In
the world of boat heaters, there are a lot of positives to these types of units:
They’re tried and true, use diesel fuel (as opposed to propane), have no moving
parts (except a fan during startup) and are easy to use. They’re also economically
priced. A Dickinson Antarctic Floor Mounted Diesel Heater (their largest unit) is
$899 with an additional $300 or so in materials. And they’re economical to use,
costing less than US$3.00 for 24 hours of running time.
There
are also some negatives to these types of units: They’re spec’d for smaller
boats (30 to 40 feet). They’re only effective at heating one space rather than
the entire boat (fans can be used to circulate the heat to other areas of the
boat but not efficiently). And they shouldn’t be used while underway (or
sometimes in strong winds) because back-drafts can blow soot and smoke into the
boat.
Unfortunately,
Cambria is
compartmentalized in its layout and a bulkhead or floor mounted unit in the
salon wouldn’t service the aft cabin or v-berth. More importantly, we don’t
have the bulkhead or floor space to accommodate one. And then, of course,
there’s the chimney. Cutting a 3-inch hole through the cabin top for the flue
isn’t something either of us was willing to do. So, we needed to move on to
central heating, a more expensive option.
Forced Air Heaters
The
simplest type of forced-air heater is probably the Red Dot which uses engine
coolant that’s been circulated through a heat exchanger and a fan to blow
heated air into a living space. But it only works when the engine is running so,
once again, this wasn’t a viable option for us.
Webasto
and Espar are probably the best known forced air heaters on the market. Both
companies build for buses and trucks but also offer marinized units for boats
in several different sizes to service boats up to 38 feet, though Espar has
come out with a newer model (the Airtronic D5) which, according to the specs,
will heat sailboats in the 45-foot range**.
![]() |
| Graphic courtesy of Espar. |
With
forced air systems, the burner draws combustion air from outside the boat as
well as from inside and burns it in a chamber with an air-to-air heat
exchanger. A blower unit then forces the heated air through flexible ducting to
outlets in the boat. The furnace unit is designed to be installed inside the
engine room or someplace out of sight. Most burn diesel, consuming 0.02
(lowest) to 0.17 (highest) gallons per hour, so close proximity to the tanks is
helpful. They also require battery power and draw anywhere from 0.67 (lowest)
amps to 7.1 (highest) amps when they’re running, depending on the size.
Prices
for the furnace units range from $1,000 for a 7,000 BTU unit to over $3,800 for
a 18,000 BTU unit. Additional costs include the fuel pickup line, exhaust hose,
through hull, electrical wiring, thermostat, ducting, fan units, and registers.
![]() |
| Graphic courtesy of Webasto. |
While
forced air systems are simpler and less expensive to install than hydronic
(coolant) systems, the ducting is 4 inches and can be difficult to accommodate
on some boats. Another downside is that heat is controlled by a central
thermostat so all spaces are heated at the same rate – if it’s 70° F in the
salon, it’s going to be 70° F in the aft cabin whether it needs to be or not. They’re
also very loud. They do, however, offer heat quickly.
![]() |
| Photo courtesy of Wallas. |
Wallas,
a company out of Finland, has introduced a forced air heating system to the
market that is supposed to be quieter and more efficient than Webasto and Espar
while offering options that can service boats up to 46 feet in the same price
range. But they also require ample room for large duct work (3 inches) and,
once again, heat is controlled by a central thermostat.
Hydronic Heaters
![]() |
| Graphic courtesy of Espar. |
Hydronic
furnaces (boilers or systems) use an air-to-water heat exchanger to heat a
coolant mixture and a pump to circulate it through silicone hoses to fan-forced
radiators. The fan speed can be adjusted manually (low and high speed) and
temperature controlled by one or more thermostats placed in zones throughout
the boat. For example, aboard Cambria,
we have three zones set up – one in the v-berth, one in the salon/galley and
one in the aft cabin – and can have the thermostat set at 68°F in the salon
while keeping it turned off in our stateroom.
The
boiler is fueled by diesel from the engine tanks and heats water that is
circulated throughout the boat via silicone hoses. The hoses are attached to
small radiators (heat exchangers) that trigger a fan once the water reaches a
certain temperature. The fans are controlled by thermostat and can be set up to
heat individual zones (as mentioned in the previous paragraph). As an added
benefit, incidental heating from the circulation loop helps keep bilges,
lockers and storage areas warmer and dryer when the heater is in use.
By
plumbing the heated water through a water-to-water heat exchanger, the units
can be adapted to heat domestic water, preheat the engine before starting and
(through the same heat exchanger) heat the boat from the engine (rather than
the boiler unit) while underway. Hydronic heaters also require less maintenance
than forced air heaters and, according to the research we’ve done, are less
expensive to maintain.
The
downside to a hydronic system is that there is a delay between turning the
heater on and receiving hot air because of the additional time it takes to heat
the water and circulate it to the heat exchangers. They’re also a more
expensive option than forced air systems. The basic components are similarly
priced, but the added cost of labour for the installation is higher due to the
amount of time needed (80 to 120 hours). They’re also not as efficient. For
example, the 31,000 BTU Webasto Thermo Pro 90 consumes 0.24 gallons of diesel
per hour and uses 7 to 11.5 amps of power.
Hydronic
systems are more difficult to price and can require working directly with a
distributor for an exact quote. But you can expect to pay $2,000 to $3,500 for
the furnace unit and that again for the additional required parts (fan coils,
thermostats, wiring, silicone hoses, through-hull, exhaust hose, valves,
fittings, pumps etc.). But while hydronic heaters may be the most expensive
option on the market, they’re also considered to be the best and most
versatile.
In
my next blog post on choosing a heater, I’ll discuss which unit we chose and
why along with information about the installation.
*Wallas and other companies also make diesel ovens and
stoves that can be used as a cabin heater but, because they weren’t a suitable
option for Cambria, I’ve chosen not to include them
in this blog post.
**Unit size is determined by the number of cubic feet to
be heated. A good rule of thumb is to multiply the cubic footage by 12
(sailboats) or 15 (powerboats) to arrive at the number of BTUs required.